Resources

Knowledge centre and brochures

Practical insights on pharmaceutical water, RO and water efficiency from our founder Manojkumar Singh, plus product brochures to download.

Knowledge centre

Technical articles

11 articles from 24+ years of designing and operating high-purity and industrial water systems.

WATER EFFICIENCYApr 2026 · Manojkumar Singh

97% recycling is not the goal. Shrinking fresh-water intake is.

Two plants can both claim 97% recycling while one wastes twice as much water. Real sustainability is measured in absolute fresh-water consumption, not percentages.

Show full articleHide full article

Another Earth Day. Another round of “Save Water” messages. As engineers, many of us have seen and shared these messages year after year. But let me ask a more uncomfortable question: behind the slogans and behind the sustainability reports, do we truly understand how to audit, implement and actually reduce water footprint in industrial systems?

A few years ago, I sat across the table with the Chairman of a large Chemicals & API group. We spent hours reviewing his water systems. The findings were clear:

  • Outdated, low-cost design choices in water treatment
  • Significant inefficiencies in water usage
  • Over 50% of raw water ending up as effluent

I demonstrated how, with current technologies, the effluent load coming from his water treatment plant could be reduced by nearly 50% immediately. His response? “We already achieve 97% recycling. That’s the best possible.” He went on to explain that since low-pressure steam for the Zero Liquid Discharge (ZLD) system came from cogeneration, the additional load “didn’t really cost anything.”

I chose not to argue further. Because the issue wasn’t technology. It was perspective.

Let’s simplify this:

  • A 3% loss from 200 m³/day fresh feed = 6 m³/day lost
  • A 3% loss from 100 m³/day fresh feed = 3 m³/day lost

Both claim 97% recycling. But which one is truly conserving water? This is where the real gap lies. Sustainability is not about showcasing high recycling percentages. It is about reducing the absolute consumption of fresh water. The Law of Conservation of Mass applies to all of us.

The real question is: are we working to shrink the denominator (fresh-water intake), or are we comfortable optimising percentages on paper? Are we designing systems, or repeating templates? Are we optimising costs, or optimising resources? Are we solving the problem, or reporting around it?

Let’s work for the planet and not just for presentations. Because real sustainability is not measured in percentages. It is measured in decisions.

Originally posted on LinkedIn by Manojkumar Singh. Follow on LinkedIn → · Questions? sales@maanviecotech.com

RO & PRETREATMENTApr 2026 · Manojkumar Singh

High hardness and high reactive silica ahead of RO

Every water-treatment professional has faced it. A pretreatment approach that targets the lowest total cost of ownership instead of the traditional softener.

Show full articleHide full article

As water-treatment personnel, every one of us has faced it. If you are managing challenges with high hardness and high reactive silica upstream of your RO system, there is a sustainable solution designed to achieve the lowest Total Cost of Ownership (TCO).

An advanced approach addresses these challenges head-on by:

  • Eliminating the high operational expenses of traditional water softeners
  • Reducing water and chemical consumption
  • Extending RO membrane life through superior silica removal

The result is a streamlined, cost-effective process that delivers immediate operational improvements. Ready to modernise your water-treatment strategy? Let’s connect and discuss how we can optimise your facility’s performance.

Originally posted on LinkedIn by Manojkumar Singh. Follow on LinkedIn → · Questions? sales@maanviecotech.com

RO & PRETREATMENTApr 2025 · Manojkumar Singh

Why pH 6.5 for hard water and pH 8.5 for soft water with silica is best for RO feed

Adjusting RO feed pH to the feed-water chemistry controls scaling: lower pH keeps calcium soluble, higher pH keeps silica dissolved.

Show full articleHide full article

For high-hardness feed (pH ~6.5), lowering the pH minimises the Langelier Saturation Index (LSI), keeping calcium and magnesium soluble and reducing the risk of scaling. Calcium carbonate’s solubility increases at lower pH, protecting the RO membrane.

For soft water with silica (pH ~8.5), silica remains dissolved at alkaline pH, preventing silica scaling. The slightly higher pH stabilises water chemistry, especially in the absence of hardness minerals, and avoids silica polymerisation.

These pH adjustments optimise RO system performance by controlling scaling tendencies based on feed-water chemistry. Do not forget to choose the correct anti-scalant.

For a Purified Water generation plant RO, always choose soft water to avoid scaling and performance issues.

Originally posted on LinkedIn by Manojkumar Singh. Follow on LinkedIn → · Questions? sales@maanviecotech.com

PHARMACEUTICAL WATERApr 2025 · Manojkumar Singh

Planning an injectable plant? Consider Cold WFI

For pharma teams planning injectable plants and WFI units, a Cold WFI system offers energy efficiency, lower operating cost and a more sustainable footprint.

Show full articleHide full article

Attention to all pharma community members involved in planning injectable plants and WFI units: consider the Cold WFI system as a viable option for your operations.

This choice not only benefits future generations and promotes energy efficiency but also contributes to minimising operational expenses. Embracing this system can lead to significant advantages in terms of sustainability and cost-effectiveness.

Should you have any enquiries or require further clarification, feel free to reach out. I am available to discuss any questions you may have regarding the implementation of a Cold WFI system. Let’s work together towards a more sustainable and efficient future for the pharmaceutical industry.

Originally posted on LinkedIn by Manojkumar Singh. Follow on LinkedIn → · Questions? sales@maanviecotech.com

PHARMACEUTICAL WATERApr 2025 · Manojkumar Singh

Burkholderia cepacia complex (BCC): what non-sterile manufacturers must know

The US FDA has advised drug manufacturers to test for BCC, a group of gram-negative bacteria linked to deficient water-system design and maintenance.

Show full articleHide full article

Microbiologists in non-sterile formulations: please update yourself on Burkholderia cepacia complex (BCC). BCC is a group of gram-negative bacteria comprising more than 20 species that has been linked to multiple instances of opportunistic infections.

Deficient manufacturing practices, particularly in the design, control and maintenance of water systems, have led to contamination with BCC and other water-borne opportunistic pathogens. Patients exposed to BCC contamination may be at increased risk of illness, especially patients with compromised immune systems or who are otherwise susceptible to infection.

The US FDA has advised drug manufacturers to watch out and test for these species. So if you are not doing it already and have a pending audit, please start the testing and make sure your raw water and Purified Water are free from it.

Originally posted on LinkedIn by Manojkumar Singh. Follow on LinkedIn → · Questions? sales@maanviecotech.com

PHARMACEUTICAL WATERMar 2025 · Manojkumar Singh

Removing endotoxins with ultrafiltration: why 10 kDa or lower

Endotoxin LPS compounds sit in the 10–20 kDa range, so a UF membrane rated at 10k MWCO or lower is recommended for endotoxin-free Purified Water and Cold WFI.

Show full articleHide full article

Endotoxins or pyrogens, the remnants of gram-negative bacteria, consist of lipopolysaccharide (LPS) compounds, each with a molecular weight ranging between 10 and 20 kDaltons.

To effectively eliminate them from Purified Water, an ultrafiltration (UF) system with a molecular weight cut-off (MWCO) of 10k or lower is recommended. UF membranes designed for this purpose undergo rigorous testing and are rated accordingly, ensuring their effectiveness.

Opting for a UF membrane with a proven track record in this application is advisable, including for post-EDI UF in Cold WFI systems.

Originally posted on LinkedIn by Manojkumar Singh. Follow on LinkedIn → · Questions? sales@maanviecotech.com

RO & PRETREATMENTMar 2025 · Manojkumar Singh

The correct dosing sequence before RO

pH correction first, then SMBS, then anti-scalant. A small but often ignored subject, and why the order matters for ORP measurement.

Show full articleHide full article

Dosing sequence for RO systems is a small but often ignored subject. The correct sequence is pH correction, then SMBS dosing, then anti-scalant dosing, whether you are maintaining alkaline pH with soft water being fed or acidic pH with hard water being fed.

pH correction is always done first, as ORP values are dependent on pH. The correlation of chlorine with ORP value varies with pH, so stabilising the pH ensures that you measure the ORP correctly.

The sequence of sensors is also important. Needless to say, proper pipe length for mixing before measurement is crucial here. Anti-scalant is dosed last for its effectiveness.

Originally posted on LinkedIn by Manojkumar Singh. Follow on LinkedIn → · Questions? sales@maanviecotech.com

PHARMACEUTICAL WATERMar 2025 · Manojkumar Singh

Microbial limits for Purified Water and WFI: what USP actually says

USP specifies only upper limits (100 CFU/ml for PW, 10 CFU/100 ml for WFI) and puts the onus on the user to define design, alert and action levels.

Show full articleHide full article

The US Pharmacopoeia does not define fixed microbial limits for Purified Water or WFI. Rather than doing that, it puts the onus on the user to do so. Depending on the criticality of the product, you need to define the design limits and the alert and action levels.

USP has only specified the upper limit, which is 100 CFU/ml for Purified Water and 10 CFU/100 ml for WFI. So the correct answer to “what is the microbial limit?” is both: an upper limit exists, and the working limits are user-defined based on the product.

Further reading recommended on this subject: USP <1231>.

Originally posted on LinkedIn by Manojkumar Singh. Follow on LinkedIn → · Questions? sales@maanviecotech.com

PHARMACEUTICAL WATERFeb 2025 · Manojkumar Singh

Which pharmacopoeia first accepted membrane-based WFI? Japan.

As early as 1988, the Japanese Pharmacopoeia (JP11) allowed WFI by RO and/or UF, years before Europe and the US accepted non-distillation methods.

Show full articleHide full article

As early as 1988, the Japanese Pharmacopoeia (JP11) specified two methods of WFI preparation: (a) distillation and (b) RO and/or UF membrane-based water processing.

However, only in 2005 (JP15) did Japan publish guidance for preparation and quality control in the general section. After 2005, Japanese manufacturers gained confidence and started using it.

Today it is quite common to find Japanese pharma companies using technologies such as DM or RO+EDI followed by membrane technologies (RO and/or UF) for producing WFI.

Originally posted on LinkedIn by Manojkumar Singh. Follow on LinkedIn → · Questions? sales@maanviecotech.com

PHARMACEUTICAL WATERFeb 2025 · Manojkumar Singh

Dead legs in pharma water systems: the WHO 3D guideline, and why to design for zero

WHO moved from 1.5D (TRS 929, 2005) to 3D (TRS 970, 2012) to accommodate legacy systems. For greenfield plants, aim for zero dead leg.

Show full articleHide full article

Most people expect the answer to be 1.5D, but the current WHO guideline is 3D. Surprisingly, it is true. WHO, in its Technical Report Series (TRS 929) published in 2005, had already revised the guideline to 1.5D (page 54). However, many legacy systems already in operation could not meet this criterion, so in TRS 970 (page 83), published in 2012, WHO revised the guideline to 3D.

This information is handy for project managers and personnel aiming for WHO approvals for existing facilities. As is evident, WHO may in the long term revise it to 1.5D again, as it has done once before.

For greenfield facilities, I would recommend that you go for zero dead leg. Technologies, fittings and valves are available to achieve this target, and it will hold you in good stead for years to come.

Originally posted on LinkedIn by Manojkumar Singh. Follow on LinkedIn → · Questions? sales@maanviecotech.com

PHARMACEUTICAL WATERFeb 2025 · Manojkumar Singh

Does a 254 nm UV purifier kill micro-organisms?

UV alters microbial DNA so organisms cannot reproduce. Why a standalone UV unit is not foolproof microbial control.

Show full articleHide full article

In the context of UV purifiers, it is essential to clarify a common misconception. UV light does not directly kill micro-organisms; instead, it alters their DNA, hindering reproduction. In UV purifier terminology, the word “kill” is used to indicate that bacteria are unable to reproduce and lose their ability to multiply.

Consequently, during testing, the modified bacteria may not be detected. Testing for bacteria involves incubating them in a conducive environment, and each colony detected is assumed to have grown from a single viable organism capable of reproduction. However, if conditions favour their survival, their vitality could potentially return.

Therefore, UV purifiers on a standalone basis may not offer foolproof micro-organism treatment. Effective solutions often combine UV treatment with other unit operations to reduce or eliminate bacteria.

Originally posted on LinkedIn by Manojkumar Singh. Follow on LinkedIn → · Questions? sales@maanviecotech.com